架空輸電線路微地形區(qū)風(fēng)害故障分析及防治方法研究

來(lái)源:電工電氣發(fā)布時(shí)間:2017-12-19 14:19 瀏覽次數(shù):3
架空輸電線路微地形區(qū)風(fēng)害故障分析及防治方法研究
 
杜志強(qiáng)1,徐玉華2,陳泓1,劉威峰2,馬云龍2,常彬2
(1 國(guó)網(wǎng)寧夏電力有限公司,寧夏 銀川 750001;2 國(guó)網(wǎng)寧夏電力有限公司電力科學(xué)研究院,寧夏 銀川 750002)
 
    摘 要:針對(duì)西北某省微地形區(qū)域近年來(lái)頻繁發(fā)生風(fēng)害跳閘的情況,通過(guò)收集風(fēng)偏、倒塔、異物短路等故障發(fā)生時(shí)的氣象條件、環(huán)境信息等,對(duì)該區(qū)域2010—2017年所發(fā)生的風(fēng)害故障進(jìn)行了統(tǒng)計(jì)分析,研究了各類型防風(fēng)害措施的優(yōu)缺點(diǎn),并根據(jù)不同風(fēng)害類型的特點(diǎn)提出有針對(duì)性防風(fēng)害措施及建議,為輸電線路防風(fēng)害工作提供參考。
    關(guān)鍵詞:輸電線路;微地形;風(fēng)害故障;防治措施
    中圖分類號(hào):TM726.3     文獻(xiàn)標(biāo)識(shí)碼:B     文章編號(hào):1007-3175(2017)12-0042-04
 
Study on Analysis and Prevention Methods of Wind Damage Fault in Micro Terrain Region of Overhead Transmission Line
 
DU Zhi-qiang1, XU Yu-hua2, CHEN Hong1, LIU Wei-feng2, MA Yun-long2, CHANG Bin2
(1 State Grid Ningxia Electric Power Co.,Ltd, Yinchuan 750001, China;
2 Power Research Institute of State Grid Ningxia Electric Power Co.,Ltd, Yinchuan 750002, China)
 
    Abstract: Aiming at the frequent occurrence of wind damage tripping in micro terrain region of certain northwest province in recent years, according to the collection of meteorological conditions and environmental messages when the faults such as windage yaw, surge tank and foreign short circuit etc happened, this paper carried out statistic analysis of wind damage faults happening from 2010 to 2017 in the region and studied on the relative merits of various types of wind damage prevention measures. According to the characteristics of different types of wind damages, this paper proposed the countermeasures for wind damage and suggestions, which provides references for the transmission line wind damage prevention work.
    Key words: transmission line; micro terrain; wind damage fault; prevention measures
 
參考文獻(xiàn)
[1] 王璋奇,陳海波,周邢銀. 埡口型微地形對(duì)輸電線路風(fēng)載荷影響的分析[J]. 華北電力大學(xué)學(xué)報(bào)( 自然科學(xué)版),2008,35(4):23-26.
[2] 祝永坤,劉福巨,江柱. 微地形微氣象地區(qū)輸電線路風(fēng)偏故障分析及防范措施[J]. 內(nèi)蒙古電力技術(shù),2014,32(2):11-14.
[3] 王超. 因風(fēng)偏引起線路跳閘的事故[J]. 科技創(chuàng)新導(dǎo)報(bào),2015(27):65-66.
[4] 李永飚,鄭建欣. 輸電線路防風(fēng)害措施和方法[J].燈與照明,2016,40(2):54-56.
[5] 常彬,陳泓,馬波. 寧夏風(fēng)區(qū)分布特征及輸電線路防風(fēng)策略研究[J]. 寧夏電力,2015(6):11-17.