550 kV GIS用盆式絕緣子的絕緣設(shè)計研究
黃坤鵬,朱傳運,王小東
(河南平高電氣股份有限公司,河南 平頂山 467001)
摘 要:作為氣體絕緣金屬封閉開關(guān)設(shè)備(GIS)中核心元件,盆式絕緣子絕緣設(shè)計關(guān)系到GIS整體的絕緣水平。闡述了盆式絕緣子設(shè)計思路,對其結(jié)構(gòu)形式進行了分析,結(jié)合電場及制造工藝給出最優(yōu)形狀比,提出了盆式絕緣子設(shè)計過程中關(guān)鍵位置電場校驗判據(jù),并通過試驗驗證了所提出校驗判據(jù)的合理性。
關(guān)鍵詞:盆式絕緣子;絕緣設(shè)計;雷電沖擊電壓
中圖分類號:TM216 文獻標識碼:A 文章編號:1007-3175(2018)10-0015-04
Insulation Design of Basin-Type Insulator in 550 kV Gas-Insulated Switchgear
HUANG Kun-peng, ZHU Chuan-yun, WANG Xiao-dong
(Henan Pinggao Electric Co., Ltd, Pingdingshan 467001, China)
Abstract: The basin-type insulator as the core component in gas-insulated switchgear (GIS), its insulation design affects insulation level of entire GIS.This paper expounded the design thought of basin-type insulator and analyzed its structural style. Combining with the electric field and manufacturing process, this paper gave the optimal shape proportion and proposed the electric field check criterion of the key location in the design process of basin-type insulator. The test verified the rationality of proposed check criterion.
Key words: basin-type insulator; insulation design; lightning impulse voltage
參考文獻
[1] 賈志杰,甘德剛,李晶.±500 k V氣體絕緣金屬封閉輸電線路絕緣尺寸設(shè)計[J]. 電網(wǎng)技術(shù),2011,35(8):192-196.
[2] 施衛(wèi)華, 阮寧暉, 王進. 高壓開關(guān)電器的發(fā)展及應用[J]. 昆明冶金高等??茖W校學報,2005,21(5):45-51.
[3] 劉英. 盆式絕緣子的設(shè)計思路研究[J]. 電氣制造,2013(8):48-52.
[4] 王毅,李勇.550 kV GIS盆式絕緣子表面含金屬微粒時的電場分析[J]. 現(xiàn)代工業(yè)經(jīng)濟和信息化,2014,4(7):94-95.
[5] 高有華,王彩云,劉曉明,等. 盆式絕緣子存在自由金屬顆粒時的電場分析及其對沿面閃絡(luò)的影響[J]. 電工電能新技術(shù),2015,34(8):56-61.
[6] 黎斌. GIS盆式絕緣子金屬外圈及屏蔽內(nèi)環(huán)設(shè)計的必要性[J]. 高壓電器,2012,48(8):109-113.