模擬量輸入合并單元計(jì)量性能檢測(cè)研究
梁凱1,張博2,朱慧1
(1 國(guó)網(wǎng)江蘇省電力有限公司無錫供電分公司,江蘇 無錫 214002;
2 國(guó)網(wǎng)江蘇省電力有限公司徐州供電分公司,江蘇 徐州 221006)
摘 要:針對(duì)模擬量輸入合并單元計(jì)量誤差特性及相關(guān)測(cè)試項(xiàng)目,研究了檢測(cè)裝置的技術(shù)方案。提出了基于時(shí)鐘同步法的信號(hào)生成技術(shù),降低了相位噪聲;采用自適應(yīng)直流供電系統(tǒng)和熱保護(hù)技術(shù),增強(qiáng)裝置可靠性;構(gòu)建了基于 NI PCI-4472 的合并單元校驗(yàn)系統(tǒng),滿足 0.2 級(jí)及以下等級(jí)合并單元測(cè)試。對(duì)三個(gè)廠家的合并單元進(jìn)行了測(cè)試,結(jié)果表明,所測(cè)合并單元的部分計(jì)量性能需要提高才能確保電能計(jì)量準(zhǔn)確。研究結(jié)果可推進(jìn)相關(guān)標(biāo)準(zhǔn)制定,有利于提升數(shù)字化電能計(jì)量系統(tǒng)的可靠性和準(zhǔn)確度,促進(jìn)智能電網(wǎng)建設(shè)。
關(guān)鍵詞:智能變電站;數(shù)字化電能計(jì)量系統(tǒng);模擬量輸入合并單元;計(jì)量性能檢測(cè)裝置
中圖分類號(hào):TM933.4 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):1007-3175(2021)11-0051-04
Research on Metering Performance Testing of Analog-Input Merging Unit
LIANG Kai1, ZHANG Bo2, ZHU Hui1
(1 Wuxi Power Supply Company of State Grid Jiangsu Electric Power Co., Ltd, Wuxi 214002, China;
2 Xuzhou Power Supply Company of State Grid Jiangsu Electric Power Co., Ltd, Xuzhou 221006, China)
Abstract: This paper examined the technical solution for detection devices for the measurement error characteristics of the analog-input merging unit and related test items. It proposed a signal generation technology based on the clock synchronization method to reduce phase noise.It used an adaptive DC power supply system and thermal protection technology to enhance the device’s reliability. It also constructed a merging unit verification system based on NI PCI-4472 to meet the merging unit test of level 0.2 and below. By testing the combined units of the three manufacturers, the results showed that part of the measurement performance of the tested combined units needs to be improved to ensure the accuracy of electric energy measurement. The research result can promote the formulation of relevant standards, which is conducive to improving the reliability and accuracy of the digital electric energy measurement system and promoting the construction of smart grids.
Key words: intelligent substation; digital electric energy metering system; analog-input merging unit; metering performance detection device
參考文獻(xiàn)
[1] 蔣博,徐文志,楊坤,等. 智能變電站過程層采樣數(shù)據(jù)組網(wǎng)傳輸分析[J] . 電工電氣,2012(5) :16-20.
[2] 程含渺,夏國(guó)芳,梁凱. 一起數(shù)字化電能計(jì)量系統(tǒng)故障現(xiàn)場(chǎng)排查[J]. 電工電氣,2018(2) :42-44.
[3] 陳霞君,劉少凡,張濟(jì)韜,等. 現(xiàn)代電能計(jì)量系統(tǒng)綜述[J]. 電工電氣,2015(1) :1-4.
[4] 朱賀,丁泉,程成,等. 智能變電站合并單元應(yīng)用現(xiàn)狀與展望[J]. 電工電氣,2015(6) :5-9.
[5] 張博君.DDS 任意波形發(fā)生器研究[J]. 現(xiàn)代電子技術(shù),2012,35(14) :100-102.
[6] 李志堅(jiān),曾大治,龍騰.DDS 相位截?cái)嚯s散分析[J].信號(hào)處理,2009,25(11) :1706-1709.
[7] 王建新,劉國(guó)歲,朱偉強(qiáng). 一種 DDS/PLL 混合型高分辨率頻率合成器[J] . 電子測(cè)量與儀器學(xué)報(bào),1999,13(4) :72-75.
[8] 金數(shù)波,鄧賢進(jìn),王豪才. 相位舍入對(duì)直接數(shù)字頻率合成雜散特性的影響[J] . 系統(tǒng)工程與電子技術(shù),2002,24(10) :16-18.
[9] 張明珠,李開成,李振興,等. 基于高精度采集卡的電子式互感器校驗(yàn)系統(tǒng)設(shè)計(jì)[J] . 電力系統(tǒng)保護(hù)與控制,2010,38(15) :114-118.