多類型DG接入配電系統(tǒng)的可靠性影響研究
晏維
(貴州大學(xué) 電氣工程學(xué)院,貴州 貴陽 550025)
摘 要:分析了分布式電源(DG) 接入模式和運(yùn)行方式對配電系統(tǒng)的可靠性影響,從可靠性評估涉及的評價指標(biāo)、計算模型及評估方法三方面闡述多類型DG 接入對配電系統(tǒng)的影響。總結(jié)了現(xiàn)有研究現(xiàn)狀及進(jìn)展,并指出未來的研究應(yīng)該著重于充分體現(xiàn)DG 與配電系統(tǒng)之間的一體性和相互作用機(jī)理,為后續(xù)對含有DG 的配電系統(tǒng)可靠性研究提供參考。
關(guān)鍵詞:分布式電源;配電系統(tǒng);可靠性
中圖分類號:TM715;TM732 文獻(xiàn)標(biāo)識碼:A 文章編號:1007-3175(2016)10-0001-05
Reliability Influence Research of Multi-Type Distributed
Generation Access Power Distribution System
YAN Wei
(School of Electrical Engineering, Guizhou University, Guiyang 550025, China)
Abstract: Analysis was made to the reliability influence of distributed generation (DG) access mode and operation mode. This paper expounded the impacts of multi-type distributed generation access on the power distribution system from the three aspects of evaluation index, calculation model and assessment method related to the reliability assessment and summarized the existing research status and progress. It is pointed out that the future research should lay emphasis on fully reflecting oneness between DG and power distribution system and mechanism of mutual action, which provides references for the reliability consideration of power distribution system with DG in future.
Key words: distributed generation; power distribution system; reliability
參考文獻(xiàn)
[1] 尤毅,劉東,于文鵬,等.主動配電網(wǎng)技術(shù)及其進(jìn)展[J]. 電力系統(tǒng)自動化,2012,36(18):10-14.
[2] 馬釗,梁惠施,蘇劍. 主動配電系統(tǒng)規(guī)劃和運(yùn)行中的重要問題[J]. 電網(wǎng)技術(shù),2015,39(6):1499-1504.
[3] 王浩鳴. 含分布式電源的配電系統(tǒng)可靠性評估方法研究[D]. 天津:天津大學(xué),2012.
[4] 袁兆祥,孔祥玉,趙帥. 分布式電源接入配電系統(tǒng)可靠性分析方法[J]. 電力系統(tǒng)及其自動化學(xué)報,2013,25(4):112-116.
[5] 蘆晶晶,趙淵,趙勇帥,等. 含分布式電源配電網(wǎng)可靠性評估的點(diǎn)估計法[J]. 電網(wǎng)技術(shù),2013,37(8):2250-2256.
[6] 別朝紅,李更豐,王錫凡. 含微網(wǎng)的新型配電系統(tǒng)可靠性評估綜述[J]. 電力自動化設(shè)備,2011,31(1):1-6.
[7] 雷振,韋鋼,蔡陽,等. 含分布式電源區(qū)域節(jié)點(diǎn)的配電網(wǎng)模型和可靠性計算[J]. 電力系統(tǒng)自動化,2011,35(1):39-43.
[8] 陳璨,吳文傳,張伯明,等. 基于多場景技術(shù)的有源配電網(wǎng)可靠性評估[J]. 中國電機(jī)工程學(xué)報,2012,32(34):67-73.
[9] 龔劍波,黃民翔,孫飛飛. 基于GO法的含分布式電源的配電系統(tǒng)可靠性評估[J]. 電力系統(tǒng)保護(hù)與控制,2012,40(16):90-94.
[10] ATWA Y M, EL-SAADANY E F.Reliability evaluation for distribution system with renewable distributed generation during islanded mode of operation[J].IEEE Transactions on Power Systems,2009,24(2):572-581.
[11] 葛少云,王浩鳴,王源山,等. 含分布式風(fēng)光蓄的配電系統(tǒng)可靠性評估[J]. 電力系統(tǒng)自動化,2012,36(5):16-22.
[12] 葛少云,張鑫,劉洪,等. 基于點(diǎn)估計法的有源配電網(wǎng)概率可靠性評估[J]. 電力系統(tǒng)保護(hù)與控制,2014,42(12):91-99.
[13] ATWA Y M, EL-SAADANY E F, GUISE A.Supply adequacy assessment of distribution system including wind-based DG during different modes of operation[J].IEEE Transactions on Power Systems,2010,25(1):78-86.
[14] ATWA Y M, EL-SAADANY E F, SALAMA M M A, et al.Adequacy evaluation of distribution system including wind/solar dg during different modes of operation[J].IEEE Transactions on Power Systems,2011,26(4):1945-1952.
[15] 柳睿,楊鏡非,程浩忠,等. 分布式電源并網(wǎng)的綜合評價[J]. 電力系統(tǒng)及其自動化學(xué)報,2013,25(1):34-39.
[16] 陳熾野,文亞鳳,劉自發(fā),等. 含有多種分布式電源的配電網(wǎng)綜合評估方法[J]. 電力建設(shè),2015,36(1):128-135.
[17] 趙勇帥. 含分布式電源的配電網(wǎng)可靠性評估模型研究[D]. 重慶:重慶大學(xué),2013.
[18] 王凱, 孔祥玉, 李剛, 等. 分布式電源接入對電網(wǎng)可靠性影響分析方法[J]. 廣東電力,2013,26(3):50-55.
[19] 李可,馬孝義,邢化玲. 基于分塊算法的復(fù)雜配電網(wǎng)修正的可靠性評估模型[J]. 電力學(xué)報,2009,24(6):451-453.
[20] 李可,馬孝義,邢化玲,等. 基于網(wǎng)絡(luò)等值的復(fù)雜中壓配電網(wǎng)修正的可靠性評估模型[J]. 電力學(xué)報,2010,25(2):103-106.
[21] 段東立,武小悅,鄧宏鐘. 基于時變故障率與服務(wù)恢復(fù)時間模型的配電系統(tǒng)可靠性評估[J]. 中國電機(jī)工程學(xué)報,2011,31(28):57-62.
[22] 謝瑩華,王成山. 基于饋線分區(qū)的中壓配電系統(tǒng)可靠性評估[J]. 中國電機(jī)工程學(xué)報,2004,24(5):35-39.
[23] 葛少云,王浩鳴. 基于系統(tǒng)狀態(tài)轉(zhuǎn)移抽樣的含分布式電源配電網(wǎng)可靠性評估[J]. 電力系統(tǒng)自動化,2013,37(2):28-35.
[24] 王旭東,林濟(jì)鏗. 基于網(wǎng)絡(luò)化簡的含分布式電源的配電網(wǎng)可靠性分析[J]. 電力系統(tǒng)自動化,2010,34(4):38-42.
[25] GONZALEZ-FERNANDEZ R A, LEITE DA SILVA A M. Reliability assessment of time-dependent systems via sequential cross-entropy Monte Carlo simulation[J].IEEE Transactions on Power Systems,2011,26(4):2381-2389.