提高變電站監(jiān)控信息規(guī)范率
曹娜,房藝丹,徐志靜
(國網吳忠供電公司,寧夏 吳忠 751100)
摘 要:提高變電站監(jiān)控信息規(guī)范率,可有效提升監(jiān)控效率。選取17 座變電站進行統(tǒng)計分析,發(fā)現造成變電站監(jiān)控信息規(guī)范率低的主要原因是監(jiān)控信息點表標準不統(tǒng)一。依據《變電站監(jiān)控系統(tǒng)信息采集規(guī)范》和《變電站典型信息表》,結合地區(qū)電網情況,編制各電壓等級的變電站典型信息點表,并根據典型信息點表優(yōu)化各站監(jiān)控信息。經實際驗證,有效提升了變電站監(jiān)控信息的規(guī)范率。
關鍵詞:變電站;監(jiān)控信息;規(guī)范率;典型信息點表
中圖分類號:TM63 文獻標識碼:A 文章編號:1007-3175(2017)02-0063-04
Improved Standard Rate of Substation Monitoring Information
CAO Na, FANG Yi-dan, XU Zhi-jing
(State Grid Wuzhong Power Supply Company, Wuzhong 7511 00, China)
Abstract: The improved standard rate of substation monitoring information could raise the monitoring efficiency. The seventeen substations were carried out statistical analysis. The main reason causing the low substation monitoring information standard rate was disunity monitoring information point table standard. According to substation monitoring information collection standard and substation typical information table, combined with the regional power grid situation, substation typical information point tables of every voltage classes were established, and each substation monitoring information was optimized according to the information point tables. The practical verification improves the standard rate of substation monitoring information effectively.
Key words: substation; monitoring information; standard rate; typical information point table
參考文獻
[1] 王慧娟,陳冬雪,秦志沁. 無人值班變電站集控中心監(jiān)控信息標準化設計[J]. 山西電力,2013(5):50-53.
[2] 徐鶴勇,張星,劉一峰. 寧夏330 kV主網監(jiān)控信息優(yōu)化方法[J]. 寧夏電力,2014(6):57-60.
[3] 楊勁松,杜長軍. 淺談變電站監(jiān)控信息優(yōu)化整合[J]. 科技創(chuàng)新與應用,2013(36):129.