Suzhou Electric Appliance Research Institute
期刊號: CN32-1800/TM| ISSN1007-3175

Article retrieval

文章檢索

首頁 >> 文章檢索 >> 往年索引

DCM Boost PFC變換器變占空比控制的數(shù)字實現(xiàn)方法

來源:電工電氣發(fā)布時間:2017-04-21 13:21 瀏覽次數(shù):10
DCM Boost PFC變換器變占空比控制的數(shù)字實現(xiàn)方法
 
宋俊超
(南京理工大學 自動化學院,江蘇 南京 210094)
 
    摘 要:分析了變占空比控制的基本原理,推導出該控制算法的占空比表達式,并提出了一種具有恒功率功能的變占空比控制的數(shù)字實現(xiàn)方法。基于數(shù)字信號處理器MC56F8257對80 W DCM Boost PFC變換器進行了實驗驗證。實驗結(jié)果表明,數(shù)字變占空比控制可以在較寬的輸入電壓范圍內(nèi)實現(xiàn)接近于1 的功率因數(shù),輸入電流基本無畸變。
    關(guān)鍵詞:功率因數(shù)校正(PFC);斷續(xù)模式(DCM);變占空比控制;數(shù)字實現(xiàn)
    中圖分類號:TM46     文獻標識碼:A     文章編號:1007-3175(2017)04-0031-04
 
Digital Realization Method of Variable Duty Ratio Control for Discontinuous
Current Mode Boost Power Factor Correction Converters
 
SONG Jun-chao
(School of Automation, Nanjing University of Science and Technology, Nanjing 210094, China)
 
    Abstract: This paper analyzed the basic principle of variable duty ratio control, derived the expression of duty ratio of this control algorithm and proposed a kind of variable duty ratio control digital implementation method with constant power functions. The experimental verification of discontinuous current mode (DCM) Boost power factor correction (PFC) 80 W converter was carried out based on the digital signal processor MC56F8257. The experimental results show that the digital variable duty ratio control can achieve a power factor close to 1 in a wide range of input voltages and the input current is almost no distortion.
    Key words: power factor correction; discontinuous current mode; variable duty ratio control; digital realization
 
參考文獻
[1] YE Z Z, JOVANOVIC M M.Implementation and performance evaluation of DSP-based control for constant-frequency discontinuous-conduction-mode boost PFC front end[J].IEEE Transactions on Industrial Electronics,2005,52(1):98-107.
[2] 葉開明,陳浩龍,蔡逢煌,王武.DCM Boost PFC 數(shù)字化的研究[J]. 電氣自動化,2014,36(4):47-49.
[3] CHEN F Z, MAKSIMOVIC D.Digital control for improved efficiency and reduced harmonic distortion over wide load range in boost PFC rectifiers[J].IEEE Transactions on Power Electronics,2009,25(10):760-766.
[4] ATHAB H S.A duty cycle control technique for elimination of line current harmonics in single-stage DCM boost PFC circuit[C]//IEEE Region 10 Conference,2008,18(5):1-6.
[5] 楊靖,陳新. 電感電流斷續(xù)模式下的功率因數(shù)校正數(shù)字控制解決方案[J]. 通信電源技術(shù),2007,24(1):8-10.
[6] 姚凱,阮新波,冒小晶,葉志紅. 電流斷續(xù)模式Boost 功率因數(shù)校正變換器的變占空比控制[J]. 電工技術(shù)學報,2011,26(11):14-24.